Our system
A unique approach to an age-old problem
A prefabricated, permeable block panel system that achieves 50% greater distribution than other systems.

Built to do more in less ground
The T&J Panel System was designed to overcome the challenges faced by today’s wastewater agencies, builders and developers looking for a better way to treat wastewater. Through decades of research, testing and engineering, we believe we have developed the most advanced, hassle-free onsite wastewater treatment system in its class.
T&J Panels are manufactured in house, using a proprietary aggregate and a patented chemical process.

PERMEABLE BLOCK PANEL
DISTRIBUTION PIPE
GEOTEXTILE + SAND ENVELOPE

Panel benefits
Increased capacity
Because each block panel works as a temporary holding tank, overall capacity is nearly three times greater than conventional stone and pipe trench systems. Think of it as a network of miniature septic tanks spread through the drain field, not just holding the effluent but treating it before releasing it to the soil.
Our manufacturing process heat-treats the blocks, which creates thousands of micro-pores in each granule of aggregate. The result is a hyper-permeable surface that filters and stores effluent and increases the surface area for biochemical and microbial treatment. That porosity multiplies storage and hydraulic load capacity well beyond standard gravel and pipe.
The result is a substantial reduction in the line length required, and a much smaller drain field.
Cleaner output
In a block panel system, each panel serves as an individual pretreatment unit over and above the septic tank itself. In the T&J Panel system, the engineered block matrix, an integral geotextile fabric and the surrounding sand work together to create a highly aerobic environment, ideal for treating wastewater by filtration and absorption as well as chemical and microbial transformation.
This multi-step treatment produces pretreated effluent that percolates more readily into the natural soil and prevents harmful biomat growth from clogging the soil interface over time.

HEAT-TREATED AGGREGATE
MICRO-PORES STORE EFFLUENT

Peace of mind
No one wants to install a wastewater system only to have issues a few years later. Because onsite wastewater is a regulated industry, our life expectancy data comes directly from the North Carolina Department of Health and Human Services and is limited to available data on failed systems. Based on NCDHHS data, our systems last 45 years on average, and that doesn’t count systems still in operation.
Every failed system we have inspected was the result of the wrong sand being used to envelop the system, or of grease and other contaminants going down the drain that are incompatible with any septic system.
When properly designed and installed, the T&J Panel system is a maintenance-free onsite wastewater solution that will outlast every other system in its class.
45 yrs
Average service life
~3×
Capacity of stone and pipe
NSF 40
Certified system
Before you get started
- You must know the MSS (Minimum Suitable Soil).
- Do you have your permit from the appropriate health department?
- Is the required sand readily available in your location? View sand sources
- Have you sourced an installer for your system?

Design tables
Use these tables for help designing panel block systems.
Best engineering practices for parallel distribution
| Distribution method | Line lengths from point of introduction |
|---|---|
| Low Pressure | Over 85 feet |
| Pressure Manifold | Up to 85 feet |
| Gravity Flow | Up to 67 feet |
Manufacturer’s specifications for reduced on-center spacing
Vertical panels
| Site constraints | Design capabilities |
|---|---|
| Typical install | 2 ft wide, 8 ft on-center |
| Initial and repair are panels* and 2 ft wide, 8 ft on-center will not fit | 2 ft wide, 6 ft on-center |
| Repairing a lot and 2 ft wide, 8 ft on-center will not fit | 2 ft wide, 6 ft on-center |
Horizontal panels
| Site constraints | Design capabilities |
|---|---|
| Typical install | 3 ft wide, 9 ft on-center |
| Limited by space | 3 ft wide, 8 ft on-center |
| Initial and repair are panels and 3 ft wide, 8 ft on-center will not fit, or repairing a failing system and 3 ft wide, 8 ft on-center will not fit | 2 ft wide, 6 ft on-center* |
See page 3 of the installation manual for the manufacturer’s specifications on reduced on-center spacing.